Answer first
This page answers the question behind What should users know about ETENWOLF HB2 Pump 2 CE-LVD Test Report | Waltek Reference WTH25X07201765J? using the exported M2 source record. The short answer is: This page presents the CE Low Voltage Directive (CE-LVD) compliance test report for the ETENWOLF HB2 inflation pump. The report was issued by Waltek Testing Group (Shenzhen) Co., Ltd. , an accredited third-party safety testing laboratory based in Shenzhen, Guangdong, China. The statement applies to the model, document scope, sample, and conditions described in the source; it is not a blanket claim about every ETENWOLF product or every later production revision.
Scope and document identity
The source record is titled ETENWOLF HB2 Pump 2 CE-LVD Test Report | Waltek Reference WTH25X07201765J. It is treated here as technical evidence, not as a replacement for the original report, manual, certificate, safety data sheet, or declaration required by a destination market. Start any support or compliance answer by matching the exact model, document number, revision, and date.
What a reader should verify
- Confirm the product model and hardware or material configuration.
- Locate the original source document and check its issue date and laboratory or author.
- Read the stated method, threshold, operating condition, or warning before interpreting a result.
- Separate evidence about EMC, chemicals, battery safety, transport, operation, and measurement accuracy.
Detailed evidence from the source record
The cleaned evidence below preserves the source document’s useful headings, paragraphs, lists, and tables so a human BasePress editor can publish searchable HTML while retaining traceability.
Document Overview
This page presents the CE Low Voltage Directive (CE-LVD) compliance test report for the ETENWOLF HB2 inflation pump. The report was issued by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party safety testing laboratory based in Shenzhen, Guangdong, China.
| Field | Detail |
|---|---|
| Reference Number | WTH25X07201765J |
| Document Type | CE-LVD Safety Test Report |
| Test Report Form No. | WTX_EN IEC 60335_1_2023B |
| Date of Sample Receipt | 2025-07-31 |
| Date of Testing | 2025-07-31 to 2025-08-15 |
| Date of Issue | 2025-08-17 |
| Overall Test Result | Pass |
| Issuing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Scope | Household and similar electrical appliances — Safety and electromagnetic field exposure |
The test report covers safety requirements applicable to household and indoor-use portable electrical appliances under the IEC and European harmonised standard framework, confirming the product’s eligibility for CE marking and placement on the EU market.
Product Information
The ETENWOLF HB2, marketed under the product name PUMP 2, is a compact portable inflation pump designed for household and indoor use. It is powered via a DC connector and classified as a Class III appliance, meaning it operates on safety extra-low voltage (SELV) and does not pose the shock hazards associated with mains-connected Class I or Class II devices.
| Attribute | Value |
|---|---|
| Product Name | PUMP 2 |
| Model Number | HB2 |
| Rated Input Voltage | 5 V DC |
| Rated Input Current | 3.0 A |
| Equipment Class | Class III |
| Installation Type | Portable appliance, indoor use only |
| Supply Connection | DC Connector |
| IP Rating | IPX0 |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Country of Origin | Made in China |
As a Class III appliance, the HB2 is powered by rechargeable batteries or a low-voltage supply source. The product label must display the rated input, manufacturer name and address, model reference, and importer details when placed on the EU market. The CE mark minimum height requirement is 5 mm and the WEEE symbol minimum height is 7 mm.
Key Details
The following tables summarise the principal test clauses evaluated during the CE-LVD assessment of the HB2 under EN IEC 60335-1:2023+A11:2023.
| Clause | Test Area | Verdict |
|---|---|---|
| Clause 5 | General Conditions for Tests (nature of supply, sequence of testing) | Pass |
| Clause 6.1 | Classification — Protection against electric shock: Class III | Pass |
| Clause 6.2 | Protection against harmful ingress of water — IPX0 | N/A |
| Clause 7 | Marking and Instructions (general) | Pass |
| Clause 7.1 | Rated voltage, current, manufacturer identity, model reference on marking label | Pass |
| Clause 7.1 | Class III symbol (IEC 60417-5180) — battery-operated exemption applies | Pass |
| Clause 7.1 | Appliances supplied from detachable power supply part to recharge battery | Pass |
Test verdict codes used throughout the report:
- P (Pass) — the test object meets the requirement.
- F (Fail) — the test object does not meet the requirement.
- N/A (Not Applicable) — the test case does not apply to this product.
All applicable clauses resulted in a Pass verdict. The submitted sample was found to fully comply with the requirements of EN IEC 60335-1:2023+A11:2023 and EN 62233:2008. Testing was performed exclusively at the Waltek Shenzhen facility with no subcontracting to external laboratories.
Standards & Compliance
The ETENWOLF HB2 was evaluated against the following harmonised European standards, which support the CE marking declaration under the Low Voltage Directive (LVD) 2014/35/EU.
| Standard | Title | Scope |
|---|---|---|
| EN IEC 60335-1:2023+A11:2023 | Household and Similar Electrical Appliances — Safety — Part 1: General Requirements | Primary safety standard covering construction, marking, protection against electric shock, mechanical hazards, and thermal requirements for household appliances |
| EN 62233:2008 | Measurement Methods for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure | Defines measurement methods and limits for EMF exposure from household appliances to ensure safety for end users |
The product is classified as a Class III appliance under EN IEC 60335-1, meaning it is supplied at safety extra-low voltage (SELV). This classification is significant for CE-LVD purposes because it eliminates risks associated with mains voltages and reduces the applicable test burden accordingly. The operating input is 5 V DC at 3.0 A, well within SELV thresholds defined by IEC standards.
Compliance with these standards supports the manufacturer’s EU Declaration of Conformity (DoC) and authorises the affixing of the CE mark on the product. When placed on the EU market, the product label must also include the name and address of the EU importer.
Validity & Certification Body
The test report WTH25X07201765J was prepared and issued by Waltek Testing Group (Shenzhen) Co., Ltd., a professional third-party testing and certification laboratory operating in China with international recognition for CE, FCC, and other global compliance testing services.
How to interpret the answer
A technical document answers a bounded question. A positive test result means the submitted sample met the named requirement under the recorded method; it does not automatically establish legal market access, lifetime reliability, safe use in every environment, or equivalence to an untested revision. When a question goes beyond the source scope, say that the detail is not documented here and request the applicable companion evidence.
What this document does not prove
This rewrite does not create a new certification, warranty, regulatory filing, or product specification. It does not prove that a different model, supplier, battery cell, firmware build, or bill of materials has the same result. It also does not replace the model-specific user manual or advice from a qualified compliance, transport, or safety professional.
Practical review checklist
| Review item | Question to answer before relying on the page |
|---|---|
| Identity | Does the label and shipped configuration match the source sample? |
| Evidence | Can the report, workbook, manual, or MSDS be retrieved from the source notes? |
| Scope | Is the claim limited to the named method, threshold, date, and sample? |
| Change control | Have materials, suppliers, firmware, battery cells, or construction changed? |
| Human action | Has an editor checked the original document before publishing? |
Frequently Asked Questions
Does this page apply to every version of the product?
No. Use it for the exact model and configuration documented in ETENWOLF HB2 Pump 2 CE-LVD Test Report | Waltek Reference WTH25X07201765J; later revisions require a documented equivalence review.
Can this result be used as a general safety or legal guarantee?
No. The result is evidence for a bounded technical scope. Other requirements may need separate EMC, chemical, battery, transport, or operating documents.
What if the question asks for a value that is not shown?
Do not infer it. State that the value is not documented in this source record and request the original evidence or a qualified review.
Why keep the original document after publishing?
Because the published rewrite is an explanation. The original report or manual remains the authoritative record for traceability, audits, customer support, and change control.