Answer first
This page answers the question behind What should users know about CE-LVD Certification for ETENWOLF Vortex S7 Tire Inflator | Waltek Testing Group? using the exported M2 source record. The short answer is: This article covers the CE Low Voltage Directive (LVD) certification document issued for the ETENWOLF Vortex S7 tire inflator. The certification was conducted by Waltek Testing Group (Shenzhen) Co., Ltd. , an accredited third-party testing laboratory based in Shenzhen, China. The statement applies to the model, document scope, sample, and conditions described in the source; it is not a blanket claim about every ETENWOLF product or every later production revision.
Scope and document identity
The source record is titled CE-LVD Certification for ETENWOLF Vortex S7 Tire Inflator | Waltek Testing Group. It is treated here as technical evidence, not as a replacement for the original report, manual, certificate, safety data sheet, or declaration required by a destination market. Start any support or compliance answer by matching the exact model, document number, revision, and date.
What a reader should verify
- Confirm the product model and hardware or material configuration.
- Locate the original source document and check its issue date and laboratory or author.
- Read the stated method, threshold, operating condition, or warning before interpreting a result.
- Separate evidence about EMC, chemicals, battery safety, transport, operation, and measurement accuracy.
Detailed evidence from the source record
The cleaned evidence below preserves the source document’s useful headings, paragraphs, lists, and tables so a human BasePress editor can publish searchable HTML while retaining traceability.
Document Overview
This article covers the CE Low Voltage Directive (LVD) certification document issued for the ETENWOLF Vortex S7 tire inflator. The certification was conducted by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory based in Shenzhen, China.
- Document Type: CE-LVD Certification Statement
- Registration No.: WTH25X04079093
- Reference No.: WTH25X04079093J
- Issuing Body: Waltek Testing Group (Shenzhen) Co., Ltd.
- Issue Date: 2025-05-23
- Applicable EU Directive:LVD 2014/35/EU
- Scope: Confirms that the product has been tested against the listed standards and found in compliance with the essential requirements of the European Low Voltage Directive, permitting use of the CE marking under the manufacturer’s sole responsibility.
Product Information
The certified product is the ETENWOLF Vortex S7 tire inflator, a portable multi-voltage inflator pump designed for household and similar applications.
| Field | Details |
|---|---|
| Product Name | Inflator Pump |
| Model No. | S7 |
| Trademark | — |
| Applicant | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
Technical Specifications
The ETENWOLF Vortex S7 supports the following input power configurations, consistent with USB Power Delivery (PD) and multi-voltage charging protocols:
- 5V / 3A
- 9V / 3A
- 12V / 3A
- 15V / 3A
- 20V / 2.25A
Key Details
The certification statement confirms the following key compliance findings for the ETENWOLF Vortex S7:
| Item | Detail |
|---|---|
| Registration No. | WTH25X04079093 |
| Reference No. | WTH25X04079093J |
| Test Result | Compliant — found in compliance with all listed standards |
| CE Marking Permission | Yes — CE marking may be affixed under the manufacturer’s sole responsibility |
| Evaluation Basis | Single sample evaluation; does not imply assessment of whole production |
| Responsible Manager | Jandy So |
| Date of Issue | 2025-05-23 |
The certification statement notes that while the product has been evaluated for LVD compliance, other relevant EU Directives must also be observed by the manufacturer. The EU Declaration of Conformity and required technical documentation must be prepared prior to affixing the CE marking.
Standards & Compliance
The ETENWOLF Vortex S7 was tested against the following harmonised European standards, which provide presumption of conformity with the essential requirements of EU LVD Directive 2014/35/EU:
| Standard | Title | Scope |
|---|---|---|
| EN IEC 60335-1:2023+A11:2023 | Household and Similar Electrical Appliances — Safety: Part 1: General Requirements | General electrical safety requirements for household appliances, including protection against electric shock, energy hazards, and mechanical hazards. |
| EN 62233:2008 | Measurement Methods for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure | Defines methods for measuring electromagnetic field (EMF) exposure from household appliances to protect human health. |
Compliance with these standards demonstrates that the ETENWOLF Vortex S7 meets the safety and EMF exposure requirements mandated for sale and distribution within the European Economic Area (EEA).
Validity & Certification Body
Certification Body
The testing and certification statement was issued by:
- Laboratory: Waltek Testing Group (Shenzhen) Co., Ltd.
- Website:www.waltek.com.cn
- Tel: +86-755-3366 3308
- Fax: +86-755-3366 3309
- Email: [email protected]
- Responsible Signatory: Jandy So (Manager)
Validity
The certification document is dated 2025-05-23. As is standard for CE-LVD compliance statements, the declaration remains valid as long as the product design, components, and manufacturing processes remain unchanged and the referenced harmonised standards remain in force. Should any design changes occur, or if the standards are revised or withdrawn, the product must be re-evaluated.
Note that this statement is based on a single sample evaluation and does not imply ongoing assessment of production. The manufacturer, Guangdong Bestek Technology Co., Ltd., bears sole responsibility for maintaining compliance and correctly affixing the CE marking after preparing the required EU Declaration of Conformity and technical documentation.
Frequently Asked Questions
The CE-LVD certification confirms that the ETENWOLF Vortex S7 has been tested and found compliant with EU Low Voltage Directive 2014/35/EU. This means the product meets European safety requirements for electrical appliances and is permitted to carry the CE marking for sale within the European Economic Area.
The S7 was tested against EN IEC 60335-1:2023+A11:2023 (general safety requirements for household electrical appliances) and EN 62233:2008 (electromagnetic field measurement methods for human exposure). Both are harmonised standards under the LVD Directive.
The certification statement was issued by Waltek Testing Group (Shenzhen) Co., Ltd. (Registration No. WTH25X04079093) on 2025-05-23, signed by Manager Jandy So.
No. As stated in the certification document, the compliance statement is based on a single sample evaluation. It does not constitute an assessment of the entire production. The manufacturer is responsible for ensuring that all production units conform to the same design and meet the applicable standards.
Related Documents
For a complete compliance picture of the ETENWOLF Vortex S7 tire inflator, the following related certification and compliance documents are relevant:
How to interpret the answer
A technical document answers a bounded question. A positive test result means the submitted sample met the named requirement under the recorded method; it does not automatically establish legal market access, lifetime reliability, safe use in every environment, or equivalence to an untested revision. When a question goes beyond the source scope, say that the detail is not documented here and request the applicable companion evidence.
What this document does not prove
This rewrite does not create a new certification, warranty, regulatory filing, or product specification. It does not prove that a different model, supplier, battery cell, firmware build, or bill of materials has the same result. It also does not replace the model-specific user manual or advice from a qualified compliance, transport, or safety professional.
Practical review checklist
| Review item | Question to answer before relying on the page |
|---|---|
| Identity | Does the label and shipped configuration match the source sample? |
| Evidence | Can the report, workbook, manual, or MSDS be retrieved from the source notes? |
| Scope | Is the claim limited to the named method, threshold, date, and sample? |
| Change control | Have materials, suppliers, firmware, battery cells, or construction changed? |
| Human action | Has an editor checked the original document before publishing? |
Frequently Asked Questions
Does this page apply to every version of the product?
No. Use it for the exact model and configuration documented in CE-LVD Certification for ETENWOLF Vortex S7 Tire Inflator | Waltek Testing Group; later revisions require a documented equivalence review.
Can this result be used as a general safety or legal guarantee?
No. The result is evidence for a bounded technical scope. Other requirements may need separate EMC, chemical, battery, transport, or operating documents.
What if the question asks for a value that is not shown?
Do not infer it. State that the value is not documented in this source record and request the original evidence or a qualified review.
Why keep the original document after publishing?