ETENWOLF P400 Electric Balloon Pump — Full Specifications

The ETENWOLF P400 is a 660 W AC-powered electric balloon pump that moves 450 L/min of air — inflating a standard 11-inch latex balloon in approximately 5 seconds. It runs on AC 110 V (no 220 V version) and offers two operating modes: Touch-on (press and hold) and Auto (hands-free). Important: The P400 inflates with air, not helium — balloons will not float. It does not support 260Q long/twisting balloons due to pressure limitations; for those, the P600 is required. Maximum continuous operation is 2 hours before risk of motor overheating.

450 L/min

Max Airflow @ 0 Back-Pressure

660 W

Motor Power (AC 110 V)

~5 s

Per 11-inch Latex Balloon

2 modes

Touch-On & Auto

2 hr

Max Continuous Operation

3 colors

Orange / Purple / Blue

Important: Air Only — Balloons Will NOT Float

The P400 inflates balloons with ordinary air — not helium or hydrogen. Air-filled balloons are heavier than air and will not float or rise to the ceiling. If floating balloons are required, a helium tank and regulator are needed; the P400 is not suitable for that purpose.

Core Performance Specifications

The P400’s 660 W single motor delivers 450 L/min at zero back-pressure on AC 110 V. Measured noise levels at 1 m distance ranged from 78.4 to 82.2 dB(A) across three test conditions. The unit ships in three colors (Orange, Purple, Blue) with identical internal specifications; launched January 2025.

ParameterValueNotes
Motor Power660 WAC 110 V only; no 220 V version
Max Airflow450 L/min@ 0 back-pressure, 25 °C
11-in latex balloon inflation~5 sVisual fill method, standard balloon
Operating ModesTouch-on + AutoTouch: press & hold; Auto: hands-free
Noise Level78.4–82.2 dB(A)@ 1 m, three test conditions
Max Continuous Operation2 hrRisk of motor overheating beyond 2 hr
Gas TypeAir onlyBalloons will NOT float
Long Balloon SupportNot supported260Q twisting balloons require higher pressure (use P600)
VoltageAC 110 VNo 220 V version available
ColorsOrange / Purple / BlueSame specs, different SKUs
Launch DateJanuary 2025

2 Nozzle Types

The P400 ships with two nozzle types, both attaching by threading onto the pump outlet. The long-balloon nozzle is included for foil (mylar) balloons; the round nozzle covers standard latex balloons.

NozzleBalloon TypeAttachment
Foil balloon nozzleLong-strip foil (mylar) balloonsThread onto outlet
Round balloon nozzleStandard round latex & foil balloonsThread onto outlet

Balloon Compatibility

The P400’s pressure output covers round latex and most foil balloons. It cannot reach the pressure required for 260Q twisting/modeling balloons; use the P600 for those.

Balloon TypeP400 Compatible?Notes
11-in round latex (standard)Yes (~5 s)Most common party balloon
14-in round latexYesSlightly longer fill time
18-in foil / mylarYesUse foil balloon nozzle
260Q twisting / modeling balloonsNoRequires higher pressure — use P600

P400 vs P600 — Which Should You Choose?

The P400 (450 L/min, 660 W, single motor) suits home use and small events; the P600 (850 L/min, 600 W, dual motor with high-pressure stage) is ~89% faster in raw flow rate, supports 260Q twisting balloons through its high-pressure motor, and includes 4 nozzle types vs 2. Noise levels are similar: P400 at 78–82 dB(A) vs P600 at 82–85 dB(A).

SpecP400P600
Airflow450 L/min850 L/min
Motor660 W, single600 W, dual (incl. high-pressure)
Long / 260Q balloonsNot supportedSupported (3-mode pressure)
Nozzle types24
Noise (1 m)78–82 dB(A)82–85 dB(A)
Max continuous use2 hr2 hr
Best forHome / small parties (<100 balloons)Weddings / large events / all balloon types

Certifications & Compliance

The P400 carries an FCC certification issued by Lixun Testing (Shenzhen). CE, UL/ETL, and RoHS certifications have not been obtained for this model.

CertificationReport No.Issuing BodyDateStandard
FCC — FCC.govLCSA03055090ELixun Testing (Shenzhen)2025-04-30FCC Equipment Authorization

Frequently Asked Questions

Will P400-inflated balloons float?

No. The P400 inflates balloons with ordinary compressed air, not helium or hydrogen. Air is denser than air at room temperature; air-filled balloons sink to the floor. For floating balloons, a helium tank and regulator are required — the P400 cannot produce helium.

Can the P400 inflate 260Q twisting / modeling balloons?

No. 260Q long/twisting balloons require significantly higher pressure than round latex balloons, and the P400’s single motor does not reach that pressure level. The ETENWOLF P600 (dual motor with high-pressure stage) supports 260Q balloons through its dedicated twisting-balloon mode.

How long does it take to inflate a 11-inch balloon? How many per hour?

Approximately 5 seconds per 11-inch round latex balloon at standard inflation. Continuous operation for up to 2 hours is safe before motor overheating risk increases. Exact hourly count depends on mode and rest intervals.

P400 vs P600 — which is right for my event?

Choose the P400 for home birthday parties, small gatherings, and events where only round or foil balloons are needed. Choose the P600 for weddings, corporate events, professional balloon artists, or any event requiring 260Q twisting balloons — the P600 is 89% faster (850 vs 450 L/min) and supports all balloon types.

How long can I run the P400 continuously?

Maximum recommended continuous operation is 2 hours. Beyond 2 hours, the motor may overheat and sustain damage. After 2 hours of use, allow the unit to cool before continuing.

Does the P400 work outside the US (220 V)?

No. The P400 is rated for AC 110 V only. There is no 220 V version. Using it on 220 V circuits without a step-down transformer will damage the unit.

ZHONGSIR | Senior Technical Engineer & Product Specialist
ZHONGSIR | Senior Technical Engineer & Product Specialist

ZHONGSIR is a Senior Product Specialist at ETENWOLF, specializing in automotive electronics, portable power systems, and high-precision inflatable technology. With years of hands-on experience in hardware testing and automotive outdoor gear applications, Luca is dedicated to translating complex engineering data into clear, actionable, and reliable technical documentation for global users.